Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 198
Filter
1.
Rev. gaúch. enferm ; 45: e20230114, 2024. tab
Article in English | LILACS-Express | LILACS, BDENF | ID: biblio-1536379

ABSTRACT

ABSTRACT Objective: To verify the association between the occurrence of skin lesions due to the use of products and/or personal protective equipment and the importance attributed to preventive care among health professionals working on the front lines of the struggle against the COVID-19 pandemic. Method: Cross-sectional, analytical study, carried out between May and June 2020, with a convenience sample (n=398) of health workers from 10 professional categories. To verify the existence of an association between the occurrence of skin lesions and exposure variables, a Contingency Table was used to obtain the Prevalence Ratio and respective Confidence Intervals. Results: 260 (65.3%) participants self-declared the development of skin lesions, predominantly nurses (53.8%), women (54.0%), from public institutions (52.8%), characterized by pressure injuries (37.3%), contact/allergic dermatitis (25.8%), or both lesions simultaneously (16.5%). More than half of professionals (53.5%) used preventive products, mainly moisturizers (51.0%). Conclusion: There was probability of an association between professionals who attributed less importance to the predictor "Protocol for proper product PPE and products" and the risk of skin injuries.


RESUMEN Objetivo: Verificar la asociación entre la aparición de lesiones cutáneas por el uso de productos y/o equipos de protección personal y la importancia atribuida al cuidado preventivo entre los profesionales de la salud que trabajaran en la primera línea de defensa contra la pandemia de la COVID-19. Método: Estudio analítico transversal, realizado entre mayo y junio de 2020, con una muestra por conveniencia (n=398) de profesionales de la salud de 10 categorías profesionales. Para verificar la existencia de asociación entre la aparición o no de lesiones cutáneas y las variables de exposición, se utilizó una Tabla de Contingencia para obtener el Índice de Prevalencia y los respectivos Intervalos de Confianza. Resultados: 260 (65,3%) participantes declararon el desarrollo de lesiones cutáneas, predominantemente enfermeras (53,8%), mujeres (54,0%), de instituciones públicas (52,8%), caracterizadas por lesiones por presión (37,3%), de dermatitis contacto/alérgicas (25,8%) y ambas lesiones simultáneamente (16,5%). Más de la mitad de los profesionales (53,5%) utilizan productos preventivos, principalmente hidratantes (51,0%). Conclusión: Hubo probabilidad de asociación de riesgo entre la aparición de lesiones cutáneas y la atribución de menor importancia al factor predictor "Protocolo para el uso adecuado de productos y EPP".


RESUMO Objetivo: Verificar a associação entre ocorrência de lesão cutânea por uso de produtos e/ou equipamentos de proteção individual e importância atribuída aos cuidados preventivos entre profissionais de saúde atuantes na linha de frente durante a pandemia da Covid-19. Método: Estudo transversal, analítico, realizado entre maio e junho de 2020, com uma amostra por conveniência (n=398) de profissionais de saúde de 10 categorias profissionais. Para verificar a existência de associação entre a ocorrência ou não de lesão de pele e as variáveis de exposição utilizou-se Tabela de Contingência para obter a Razão de Prevalência e respectivos Intervalos de Confiança. Resultados: 260 (65,3%) participantes autodeclararam desenvolvimento de lesões na pele, predominando enfermeiros (53,8%), mulheres (54,0%), provenientes de instituições públicas (52,8%), caracterizadas por lesões por pressão (37,3%), dermatite de contato/alérgica (25,8%), e ambas as lesões de forma simultânea (16,5%). Mais da metade dos profissionais (53,5%) usou produtos preventivos, principalmente hidratantes (51,0%). Conclusão: Ocorreu probabilidade de associação de risco entre a ocorrência de lesão de pele e a menor importância atribuída ao fator preditor Protocolo para uso adequado de produtos e EPIs.

2.
Audiol., Commun. res ; 29: e2722, 2024. tab
Article in Portuguese | LILACS | ID: biblio-1533842

ABSTRACT

RESUMO Objetivo investigar os impactos comunicativos, sociais e emocionais gerados pela adoção de medidas protetivas contra a COVID-19 e associá-los ao grau da perda auditiva e ao tempo de uso dos aparelhos de amplificação sonora individual. Métodos estudo transversal e quantitativo, com 72 indivíduos, divididos em adultos e idosos, com perda auditiva bilateral, de grau até moderadamente severo, protetizados antes da pandemia em um programa público de saúde auditiva e que mantiveram uso efetivo dos dispositivos. Os sujeitos foram convidados a participar do estudo enquanto aguardavam consulta. Os prontuários foram acessados, a fim de coletar informações sobre o perfil audiológico e adaptação/uso dos aparelhos de amplificação sonora individual. Em sala silenciosa, foi aplicado, oralmente, protocolo contendo questões objetivas e os dados foram tabulados e submetidos aos testes estatísticos Igualdade de Duas Proporções e Qui-Quadrado. Resultados nos dois grupos, um número significativo de usuários teve a comunicação impactada pelo uso de máscaras e pelo distanciamento físico, predominando, entre os adultos, a dificuldade com as tecnologias digitais (celulares/computadores), enquanto nas videochamadas, os prejuízos comunicativos foram mais experenciados pelos idosos. Os empecilhos comunicativos e sociais existiram, independentemente do perfil audiológico e do tempo de uso dos dispositivos. Quando questionados se deixaram de se comunicar e se as medidas afetaram a sua vida social, as respostas ficaram divididas entre "sim/às vezes" e "não". Quanto ao impacto emocional das medidas protetivas, constatou-se maior repercussão entre os adultos. Conclusão as medidas protetivas afetaram a comunicação dos usuários de aparelhos de amplificação sonora individual, porém, não desencorajaram as trocas comunicativas e as interações sociais de, aproximadamente, metade da amostra, sendo o impacto emocional mais evidente nos adultos. Tais dificuldades não estiveram relacionadas ao perfil audiológico e uso diário dos dispositivos.


ABSTRACT Purpose to investigate the communicative, social, and emotional impacts generated by adopting protective measures against COVID-19 and associate them with the degree of hearing loss and the time of use of hearing aids. Methods cross-sectional quantitative study, with 72 individuals, divided into adults and older adults, with bilateral hearing loss up to moderately severe degree, users of hearing aids fitted before the pandemic in a public hearing health program who had maintained effective use of the devices. The participants were invited to participate in the study while waiting for an appointment and signed the consent form. After that, medical records were accessed to collect information about audiological profiles and the fitting/use of hearing aids. Afterward, a protocol with objective questions was orally applied in a silent room. Data were tabulated and subjected to Equality of Two Proportions and Chi-Square statistical tests. Results in both groups, a significant number of users had communication impacted by the use of masks and by social distancing, with difficulty with digital technologies (cell phones/computers) predominating among adults, while older adults more commonly experienced communicative impairments during video calls. The communicative impediment existed regardless of the audiological profile and device use time. When asked if they stopped communicating and if the measures affected their social life, the sample was divided between "yes/sometimes" and "no". As for the emotional impact of protective measures, there was a greater impact among adults. Conclusion protective measures affected the communication of hearing aids users but did not discourage communicative exchanges and social interactions for approximately half of the sample, with the emotional impact being more evident in adults. Such difficulties were not related to the audiological profile and daily use of the devices.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Social Change , Social Environment , Communication , Personal Protective Equipment , Digital Technology , Physical Distancing , COVID-19/prevention & control , Hearing Aids , Brazil/epidemiology , Risk Factors , Sickness Impact Profile , Persons With Hearing Impairments , Hearing Loss
3.
Rev. Pesqui. (Univ. Fed. Estado Rio J., Online) ; 16: e13058, jan.-dez. 2024. tab
Article in English, Portuguese | LILACS, BDENF | ID: biblio-1538026

ABSTRACT

Objetivo: analisar os fatores associados ao uso e a adesão aos equipamentos de proteção individual pelos profissionais pós-graduandos vinculados a programas de residência em saúde. Método: transversal com 227 residentes. Avaliadas variáveis relacionadas à adesão e uso adequado de equipamentos de proteção individual por meio de instrumento validado "E.P.I. covid-19 Brasil-versão adaptada para residentes". Realizou-se análise bivariada, teste qui-quadrado/exato de Fisher e cálculo da razão de prevalência. Pesquisa foi aprovada pelo Comitê de Ética em Pesquisa com Seres Humanos. Resultados: realizaram atividades de capacitação sobre EPIs (59,9%).Associação entre uso de máscara cirúrgica(p≤0,01) e idade; área de concentração do programa e uso de gorro (p≤0,01) e máscara cirúrgica (p=0,04); realização de atividades de capacitação e uso de máscara cirúrgica (p=0,02) e N95 (p≤0,01). A adesão variou de 0% a 67%. Conclusão: fatores associados ao uso adequado, idade, área de concentração do programa e realização de atividades de capacitação. Houve fragilidades na adesão. Sugere-se o fortalecimento do tema biossegurança na residência.


Objective: to analyze the factors associated with the use and adherence to personal protective equipment by graduate professionals linked to residency programs in health. Method: cross-sectional study with 227 residents. E.P.I.covid-19 Brasil-adapted version for residents". Bivariate analysis, Fisher chi-square/exact test and calculation of the prevalence ratio were performed. Research was approved by the Ethics Committee for Research with Human Beings. Results: they carried out training activities on PPE (59.9%). Association between use of surgical mask (p≤0.01) and age; program concentration area and use of cap (p≤0.01) and surgical mask (p=0.04); performance of training activities and use of surgical mask (p=0.02) and N95 (p≤0.01). Adherence to PPE ranged from 0% to 67%. Conclusion: factors associated with the proper use of personal protective equipment were age, area of program concentration, and performance of training activities. There were weaknesses in adherence. It is suggested to strengthen the theme of biosafety in the residence.


Objetivos:analizar los factores asociados al uso y la adherencia a los equipos de protección personal (EPP) por parte de profesionales graduados vinculados a programas de residencia en salud. Método: estudio transversal con 227 residentes. Se utilizó la versión adaptada para residentes del «Cuestionario sobre EPI en la atención primaria de salud (EPS-APS) en el contexto de la COVID-19 en Brasil. Se realizaron análisis bivariados, prueba chi-cuadrado de Fisher/prueba exacta y cálculo de la razón de prevalencia. La investigación fue aprobada por el Comité de Ética para la Investigación con Seres Humanos. Resultados: se realizaron actividades de capacitación sobre EPI (59,9%). Se observó asociación entre el uso de mascarilla quirúrgica (p≤0,01) y la edad; área de concentración del programa y uso de cofia (p≤0,01) y mascarilla quirúrgica (p=0,04); realización de actividades de capacitación y uso de mascarilla quirúrgica (p=0,02) y N95 (p≤0,01). La adherencia a los EPI osciló entre el 0% y el 67%. Conclusión: los factores asociados al uso correcto de los EPI fueron la edad, el área de concentración del programa y la realización de actividades de capacitación. Se observaron debilidades en la adherencia. Se sugiere fortalecer el tema de la bioseguridad en la residencia.


Subject(s)
Humans , Male , Female , Adult , Young Adult , Personal Protective Equipment/statistics & numerical data , COVID-19/prevention & control , Internship and Residency/statistics & numerical data , Internship, Nonmedical/statistics & numerical data , Containment of Biohazards/statistics & numerical data
4.
Rev. Ciênc. Plur ; 9(3): 32265, 26 dez. 2023. tab
Article in Portuguese | LILACS, BBO | ID: biblio-1524372

ABSTRACT

Introdução: As atividades laborais de manicures e pedicures geram riscos de exposições acidentais aos patógenos vinculados ao sangue como vírus, fungos e bactérias, devido à falta de adesão às medidas de biossegurança, e procedimentos de esterilização acarretando riscos à saúde dos profissionais e clientes. Objetivo:Verificar os conhecimentos das manicures e pedicures sobre os métodos de limpeza e esterilização de materiais, o uso de equipamentos de proteção individual e doenças relacionadas à profissão. Metodologia:Estudo transversal de abordagem quantitativa, realizado entre Outubro de 2017 a Janeiro de 2018, com 22 participantes finais. Incluídos os maiores de 18 anos, ambos os sexos, experiência mínima de um ano e residir em Nova Floresta. A técnica para seleção da amostra foi snowball. Resultados: A limitação de conhecimento sobre os riscos laborais na exposição de agentes infectantes, a baixa adesão no uso de equipamentos de proteção individuale a falta de padronização no processo de descontaminação, limpeza, desinfecção e esterilização dos instrumentais estão associados ao potencial risco de contaminação por agentes infecciosos, e ao acometimento de doenças infectocontagiosas por manicures, pedicures e clientela. Conclusões:Existem fragilidades no conhecimento destes profissionais,a maioria expõe métodos de antissepsia precários, devido a falta de sistematização e padronização dos procedimentos de limpeza, descontaminação dos instrumentais e o uso de equipamentos de proteção individual, além do conhecimento da profissão ter sido adquirido informalmente (AU).


Introduction: The work activities of manicurists and pedicurists generate risks of accidental exposure to pathogens linked to the blood such as viruses, fungi and bacteria, due to the lack of adherence to biosafety measures, and sterilization procedures causing risks to the health of professionals and clients. Objective:To verify the knowledge of manicurists and pedicurists on methods of cleaning and sterilizing materials, the use of personal protective equipment and diseases related to the profession. Methodology: Cross-sectional study with a quantitative approach, carried out between October 2017 and January 2018, with 22 final participants. Included are those over 18 years of age, both sexes, with at least one year's experience and residing in Nova Floresta. The technique for sample selection was snowball.Results:Limited knowledge about occupational risks in the exposure of infectious agents, low adherence to the use of personal protective equipmentand the lack of standardization in the process of decontamination, cleaning, disinfection and sterilizationof instruments are associated with the potential risk of contamination by infectious agents, and the spread of infectious diseases by manicurists, pedicurists and clientele. Conclusions:There are weaknesses in the knowledge of these professionals, most expose precarious antisepsis methods, due to the lack of systematization and standardization of cleaning procedures, decontamination of instruments and the use of personal protective equipment, in addition to the knowledge of the profession having been acquired informally (AU).


Introducción: Las actividades laborales de manicuras y pedicuras generan riesgos de exposiciónaccidental a patógenos ligados a la sangre como virus, hongos y bacterias, debido al incumplimiento de medidas de bioseguridad y procedimientos de esterilización generando riesgos a la salud de profesionales y clientes. Objetivo:Verificar los conocimientos de manicuras y pedicuras sobre métodos de limpieza y esterilización de materiales, el uso de equipos de protección personal y enfermedades relacionadas con la profesión. Metodología:Estudio transversal de abordaje cuantitativo, realizado entre octubre de 2017 y enero de 2018, con 22 participantes finales. Se incluyen los mayores de 18 años, de ambos sexos, con experiencia mínima de un año y vivir en Nova Floresta. La técnica para la selección de la muestra fue la de bola de nieve. Resultados:El conocimiento limitado sobre los riesgos laborales en la exposición de agentes infecciosos, la baja adherencia al uso de equipo de protección personal y la falta de estandarización en el proceso de descontaminación, limpieza, desinfección y esterilización de instrumentos se asocian con el riesgo potencial de contaminación por agentes infecciosos, y la propagación de enfermedades infecciosas entre manicuras, pedicuras y clientela. Conclusiones:Existen debilidades en el conocimiento de estos profesionales, la mayoría expone métodos de antisepsia precarios, debido a la falta de sistematización y estandarización de los procedimientos de limpieza, descontaminación de los instrumentos y el uso de equipo de protección Personal,además de haber adquirido los conocimientos de la profesión informalmente (AU).


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Containment of Biohazards , Beauty and Aesthetics Centers , Patient Safety , Personal Protective Equipment , Sterilization/instrumentation , Cross-Sectional Studies/methods
5.
Rev. latinoam. enferm. (Online) ; 31: e3861, ene.-dic. 2023. tab
Article in English | LILACS, BDENF | ID: biblio-1431832

ABSTRACT

Abstract Objective: to evaluate nursing professionals and patient safety culture during the professional performance in the care of suspected or infected patients with COVID-19. Method: a cross-sectional study carried out with 90 professionals from critical care units of two teaching hospitals. An instrument for sociodemographic characterization and health conditions was used, in addition to the constructs "Nursing professional and patient safety" and the Hospital Survey on Patient Safety Culture. Univariate analyzes were performed between the diagnosis of COVID-19 and the characteristics of Nursing professionals, applying Kendell's correlation between the constructs. Results: the COVID-19 diagnosis presented a significant statistical difference between nursing professionals that worked for more than six years at the critical care unit (p=0.020) and the items of the construct "Nursing professional and patient safety" regarding the doubts about how to remove the personal protective equipment (p=0.013) and safety flow (p=0,021). The dimensions 2 (p=0.003), 3 (p=0.009), 4 (p=0.013), 6 (p<0.001), and 9 (p=0.024) of the Hospital Survey on Patient Safety Culture were associated with the accomplishment of training. Conclusion: a higher professional nursing experience time was associated with non-infection by COVID-19. The perception of the safety culture of the patient was related to the accomplishment of training.


Resumo Objetivo: avaliar a segurança dos profissionais de enfermagem e a cultura de segurança do paciente durante a atuação profissional no atendimento de pacientes suspeitos ou com COVID-19. Método: estudo transversal realizado com 90 profissionais de unidades críticas de dois hospitais-escola. Foi utilizado um instrumento para caracterização sociodemográfica e condições de saúde, além dos constructos "Segurança do profissional e do paciente" e Hospital Survey on Patient Safety Culture. Foram realizadas análises univariadas entre o diagnóstico de COVID-19 e as características dos profissionais, aplicando-se a correlação de Kendell entre os constructos. Resultados: o diagnóstico de COVID-19 apresentou diferença estatisticamente significativa entre os profissionais que trabalhavam há mais de seis anos na unidade (p=0,020) e os itens do constructo "Segurança do profissional e do paciente" referentes às dúvidas sobre como retirar o equipamento de proteção individual (p=0,013) e fluxo seguro (p=0,021). As dimensões 2 (p=0,003), 3 (p=0,009), 4 (p=0,013), 6 (p<0,001) e 9 (p=0,024) do Hospital Survey on Patient Safety Culture foram associadas à realização de treinamentos. Conclusão: maior tempo de experiência profissional do profissional de enfermagem esteve associado a não infecção por COVID-19. A percepção de cultura de segurança do paciente esteve relacionada à realização de treinamentos.


Resumen Objetivo: evaluar la seguridad de los profesionales de enfermería y la cultura de seguridad del paciente durante su actuación profesional en el cuidado de pacientes sospechosos o con COVID-19. Método: estudio transversal realizado con 90 profesionales de unidades críticas de dos hospitales universitarios. Se utilizó un instrumento de caracterización sociodemográfica y de condiciones de salud, además de los constructos "Seguridad del profesional y del paciente" y Hospital Survey on Patient Safety Culture. Se realizaron análisis univariados entre el diagnóstico de COVID-19 y las características de los profesionales y se aplicó la correlación de Kendell entre los constructos. Resultados: el diagnóstico de COVID-19 mostró diferencia estadísticamente significativa entre los profesionales que actuaron por más de seis años en la unidad (p=0,020) y los ítems del constructo "Seguridad del profesional y del paciente" referentes a dudas sobre cómo retirar el Equipo de Protección Personal (p=0,013) y flujo seguro (p=0,021). Las dimensiones 2 (p=0,003), 3 (p=0,009), 4 (p=0,013), 6 (p<0,001) y 9 (p=0,024) del Hospital Survey on Patient Safety Culture se asociaron a la realización de formación. Conclusión: mayor tiempo de experiencia profesional de enfermería se asoció con la no infección por COVID-19. La percepción de la cultura de seguridad del paciente se relacionó con la realización de entrenamiento.


Subject(s)
Humans , Risk Management , Cross-Sectional Studies , Occupational Health , Critical Care , Patient Safety , Personal Protective Equipment , COVID-19/epidemiology , Hospitals, University , Nurse Practitioners , Nurses
6.
Rev. latinoam. enferm. (Online) ; 31: e3761, ene.-dic. 2023. tab, graf
Article in Spanish | LILACS, BDENF | ID: biblio-1431840

ABSTRACT

Objetivo: investigar la prevalencia de lesiones cutáneas y factores asociados con el uso de respiradores N95 en profesionales de la salud de Brasil. Método: estudio transversal realizado con 11.368 profesionales de la salud en el que se empleó un método de muestreo dirigido por encuestados adaptado para entornos en línea. Se ejecutaron análisis univariados y multivariados para investigar la asociación entre la variable "lesiones cutáneas por utilizar respiradores N95" y sexo, categoría profesional, lugar de trabajo, capacitación, diagnóstico de COVID-19 y disponibilidad de suficiente provisión de Equipo de Protección Personal de buena calidad. Resultados: la prevalencia de lesiones cutáneas fue del 61,8%. Las mujeres fueron 1,203 veces (IC 95%: 1,154-1,255) más propensas a desarrollar lesiones que los hombres. La probabilidad de lesiones cutáneas en psicólogos (RP=0,805; IC 95%: 0,678-0,956) y dentistas (RP=0,884; IC 95%: 0,788-0,992) fue menor en comparación con la encontrada en los profesionales de Enfermería. Los profesionales con diagnóstico positivo de COVID-19 y que trabajan en la Unidad de Cuidados Intensivos son más propensos a sufrir lesiones cutáneas (RP=1,074; IC 95%: 1,042-1,107); (RP=1,203; IC 95%: 1,168-1,241), respectivamente, Conclusión: la prevalencia de lesiones cutáneas causadas por utilizar respiradores N95 fue del 61,8% y estuvo asociada al sexo femenino, a la categoría profesional, al lugar de trabajo, a la capacitación, a diagnóstico de COVID-19 y a la disponibilidad de suficiente provisión de Equipo de Protección Personal de buena calidad.


Objective: to investigate the prevalence of skin lesions and factors associated with the use of N95 respirators among health professionals in Brazil. Method: cross-sectional study conducted with 11,368 health professionals using a respondent-driven sampling method adapted for online environments. Univariate and multivariate analyses were performed to investigate the association between the "skin lesions with the use of N95 respirators" variable and gender, professional category, workplace, training, COVID-19 diagnosis, and availability of sufficient and high-quality Personal Protective Equipment. Results: the prevalence of skin lesions was 61.8%. Women were 1.203 times (95% CI: 1.154-1.255) more likely to develop a lesion than men. The chances of skin lesions in psychologists (PR=0.805; 95% CI: 0.678-0.956) and dentists (PR=0.884; 95% CI: 0.788-0.992), were lower when compared to Nursing professionals. Professionals with a positive COVID-19 diagnosis and working in the Intensive Care Unit have an increased chance of presenting skin lesions (PR=1.074; 95% CI: 1.042-1.107); (PR=1.203; 95% CI: 1.168-1.241), respectively. Conclusion: the prevalence of skin lesions caused by the use of N95 respirators was 61.8% and was associated with female gender, professional category, workplace, training, COVID-19 diagnosis, and availability of sufficient and highquality Personal Protective Equipment.


Objetivo: investigar a prevalência de lesões de pele e fatores associados ao uso de respiradores N95 entre profissionais de saúde no Brasil. Método: estudo transversal realizado com 11.368 profissionais de saúde por meio de um método de amostragem dirigido por respondentes adaptado para ambientes online. Análises univariadas e multivariadas foram realizadas para investigar a associação entre a variável "lesão de pele com uso de respirador N95" e sexo, categoria profissional, local de trabalho, treinamento, diagnóstico de COVID-19 e disponibilidade suficiente de equipamentos de proteção individual de qualidade. Resultados: a prevalência de lesões cutâneas foi de 61,8%. As mulheres foram 1,203 vezes (IC 95%: 1.154-1.255) mais propensas a desenvolver uma lesão do que os homens. As chances de lesão de pele em psicólogos (RP=0,805; IC 95%: 0,678-0,956) e dentistas (RP=0,884; IC 95%: 0,788-0,992) foram menores quando comparados aos profissionais de Enfermagem. Profissionais com diagnóstico positivo para COVID-19 e que trabalham em Unidade de Cuidados Intensivos têm maior chance de apresentar lesões de pele (RP=1,074; IC 95%: 1,042-1,107); (RP=1,203; IC 95%: 1,168- 1,241), respectivamente. Conclusão: a prevalência de lesões de pele causadas pelo uso do respirador N95 foi de 61,8% e esteve associada ao sexo feminino, categoria profissional, local de trabalho, treinamento, diagnóstico de COVID-19 e disponibilidade suficiente de equipamentos de proteção individual de qualidade.


Subject(s)
Humans , Male , Female , Patient Care Team , Respiratory Protective Devices/adverse effects , Skin Diseases/epidemiology , Cross-Sectional Studies , Surveys and Questionnaires , N95 Respirators/adverse effects , COVID-19/prevention & control , COVID-19/epidemiology
7.
Arq. bras. oftalmol ; 86(4): 322-329, July-Sep. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1447374

ABSTRACT

ABSTRACT Purpose: This study aimed to use computational models for simulating the movement of respiratory droplets when assessing the efficacy of standard slit-lamp shield versus a new shield designed for increased clinician comfort as well as adequate protection. Methods: Simulations were performed using the commercial software Star-CCM+. Respiratory droplets were assumed to be 100% water in volume fraction with particle diameter distribution represented by a geometric mean of 74.4 (±1.5 standard deviation) μm over a 4-min duration. The total mass of respiratory droplets expelled from patients' mouths and droplet accumulation on the manikin were measured under the following three conditions: with no slit-lamp shield, using the standard slit-lamp shield, and using our new proposed shield. Results: The total accumulated water droplet mass (kilogram) and percentage of expelled mass accumulated on the shield under the three aforementioned conditions were as follows: 5.84e-10 kg (28% of the total weight of particle emitted that settled on the manikin), 9.14e-13 kg (0.045%), and 3.19e-13 (0.015%), respectively. The standard shield could shield off 99.83% of the particles that would otherwise be deposited on the manikin, which is comparable to 99.95% for the proposed design. Conclusion: Slit-lamp shields are effective infection control tools against respiratory droplets. The proposed shield showed comparable effectiveness compared with conventional slit-lamp shields, but with potentially enhanced ergonomics for ophthalmologists during slit-lamp examinations.


RESUMO Introdução: Os oftalmologistas têm alto risco de contrair a doença do Coronavírus-19 devido à proximidade com os pacientes durante os exames com lâmpada de fenda. Usamos um modelo de computação para avaliar a eficácia das proteções para lâmpadas de fenda e propusemos uma nova proteção ergonomicamente projetada. Métodos: As simulações foram realizadas no software comercial Star-CCM +. Os aerossóis de gotículas foram considerados 100% de água em fração de volume com distribuição de diâmetro de partícula representada por uma média geométrica de 74,4 ± 1,5 (desvio padrão) μm ao longo de uma duração de quatro minutos. A massa total de gotículas de água acumulada no manequim e a massa expelida pela boca do paciente foram medidas em três condições diferentes: 1) Sem protetor de lâmpada de fenda, 2) com protetor padrão, 3) Com o novo protetor proposto. Resultados: A massa total acumulada das gotas de água (kg) e a porcentagem da massa expelida acumulada no escudo para cada uma das respectivas condições foram; 1) 5,84e-10 kg (28% do peso total da partícula emitida que assentou no manequim), 2) 9,14e-13 kg (0,045%), 3,19e-13 (0,015%). O escudo padrão foi capaz de proteger 99,83% das partículas que, de outra forma, teriam se depositado no manequim, o que é semelhante a 99,95% para o projeto proposto. Conclusão: Protetores com lâmpada de fenda são ferramentas eficazes de controle de infecção contra gotículas respiratórias. O protetor proposto mostrou eficácia comparável em comparação com os protetores de lâmpada de fenda convencionais, mas potencialmente oferece uma melhor ergonomia para oftalmologistas durante o exame de lâmpada de fenda.

8.
Rev. bras. cir. plást ; 38(1): 1-6, jan.mar.2023. ilus
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1428714

ABSTRACT

Objective: Develop an application to guide health professionals during home care in coping with the COVID-19 pandemic. Method: The structure of the application was developed in four stages: Analysis - an integrative literature review was carried out with the Health Sciences databases, such as MEDLINE, SciELO, and LILACS. Design - this step involved planning and producing didactic content, defining topics and writing subjects, selecting media, and designing the interface (layout). Development - definition of the navigation structure and planning of the configuration of environments. Implementation - construction of an environment for downloading the application on the Internet. Results: The ORIENTA COVID-19 application has 40 screens and 130 images describing gowning, and undressing of PPE, including using a homemade mask, guidelines for care to prevent COVID-19, and social etiquette. After registration at the National Institute of Industrial Property, it will be available on the Google Play Store under ORIENTA COVID-19. Conclusion: After an integrative review of the literature obtained from the main databases, the ORIENTA COVID-19 application was developed to support health professionals during home care related to COVID-19.


Objetivo: Desenvolver um aplicativo para orientar os profissionais de saúde durante o atendimento domiciliar, no enfrentamento da pandemia da COVID-19. Método: A estrutura do aplicativo foi desenvolvida em quatro etapas: Análise - foi realizada uma revisão integrativa da literatura junto às bases de dados das Ciências da Saúde, como: MEDLINE, SciELO e LILACS. Design - esta etapa envolveu o planejamento e a produção do conteúdo didático, a definição dos tópicos e a redação dos assuntos, a seleção das mídias e o desenho da interface (layout). Desenvolvimento - definição da estrutura de navegação e o planejamento da configuração de ambientes. Implementação - construção de um ambiente para download da aplicação na Internet. Resultados: O aplicativo ORIENTA COVID-19 tem 40 telas e 130 imagens descrevendo a paramentação, desparamentação dos EPIs incluindo a técnica do uso da máscara caseira, orientações dos cuidados para prevenir a COVID-19 e a etiqueta social. Após seu registro no Instituto Nacional da Propriedade Industrial, estará disponível no Google Play Store sob o nome ORIENTA COVID-19. Conclusão: Após revisão integrativa da literatura obtida nas principais bases de dados, desenvolveu-se o aplicativo ORIENTA COVID-19, para apoio aos profissionais da saúde durante o atendimento domiciliar relacionado à COVID-19.

9.
Cogitare Enferm. (Online) ; 28: e89707, Mar. 2023. tab
Article in Portuguese | LILACS-Express | LILACS, BDENF | ID: biblio-1520770

ABSTRACT

RESUMO Objetivo: Validar o instrumento de medida que avalia o uso e a adesão de equipamentos de proteção individual entre os residentes de saúde. Método: Estudo metodológico desenvolvido em ambiente virtual entre agosto de 2020 e março de 2021 com residentes da atenção primária e hospitalar das cinco regiões do Brasil. Os participantes responderam a versão adaptada para residentes do "E.P.I.-APS". Utilizou-se a análise fatorial confirmatória para validação do instrumento. Resultados: Participaram 227 residentes, sendo maioria mulher cis (82,8%), atuavam na região Sudeste (58,1%) e em atenção hospitalar (47,6%). A estrutura em oito domínios (gorro/touca; luvas; comportamento de segurança; máscara N95; higienização das mãos; avental/capote; máscara cirúrgica; óculos de proteção/protetor facial) foi confirmada. Apenas dois itens com carga fatorial inferior a 0,5 foram mantidos. Conclusão: O instrumento é válido para mensurar o uso e adesão aos equipamentos de proteção individual entre residentes, o que contribui para direcionar a formação e a segurança laboral.


ABSTRACT Objective: To validate the measuring instrument that assesses healthcare residents' use and adherence to personal protective equipment. Method: Methodological study developed in a virtual environment between August 2020 and March 2021 with primary care and hospital residents from the five regions of Brazil. The participants answered the adapted version of the "P.P.E.-PHC" for residents. Confirmatory factor analysis was used to validate the instrument. Results: 227 residents took part, the majority of whom were cis women (82.8%), worked in the Southeast region (58.1%), and in-hospital care (47.6%). The structure in eight domains (cap, gloves, safety behavior, N95 mask, hand hygiene, apron/coat, surgical mask, goggles/face shield) was confirmed. Only two items with a factor load of less than 0.5 were kept. Conclusion: The tool is valid for measuring residents' use of and adherence to personal protective equipment, which helps to guide training and occupational safety.


RESUMEN Objetivo: Validar el instrumento de medición que evalúa el uso y la adhesión de los equipos de protección individual entre los residentes de salud. Método: Estudio metodológico desarrollado en un entorno virtual entre agosto de 2020 y marzo de 2021 con residentes de atención primaria y hospitalaria de las cinco regiones de Brasil. Los participantes respondieron a la versión adaptada del "E.P.I.-APS" para residentes. Se utilizó un análisis factorial confirmatorio para validar el instrumento. Resultados: Participaron 227 residentes, en su mayoría mujeres cis (82,8%), que trabajaban en el sureste (58,1%) y en cuidados hospitalarios (47,6%). Se confirmó la estructura en ocho dominios (gorro; guantes; comportamiento de seguridad; mascarilla N95; higiene de las manos; delantal/abrigo; mascarilla quirúrgica; gafas/protector facial). Sólo se mantuvieron dos ítems con una carga factorial inferior a 0,5. Conclusión: La herramienta es válida para medir el uso y la adhesión de los equipos de protección individual entre los residentes, lo que ayuda a orientar la formación y la seguridad laboral.

10.
Ciênc. Saúde Colet. (Impr.) ; 28(3): 789-801, Mar. 2023. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1421187

ABSTRACT

Resumo Os equipamentos de proteção individual (EPIs) devem ser adotados por todos os grupos profissionais expostos a riscos de contato com material biológico. O objetivo é analisar fatores associados à não utilização de EPIs por trabalhadores acometidos por acidentes ocupacionais com material biológico. Estudo quantitativo, transversal, em que foram analisadas fichas de notificação de acidentes de trabalho com material biológico de municípios do Sul do Brasil de 2014 a 2019. Realizou-se análise não ajustada e ajustada dos dados e, após, utilizou-se a análise hierarquizada, sendo estabelecidas associações entre variáveis independentes e o desfecho. A frequência de não uso de EPI entre os anos foi de 76,5%. Ao final da análise hierarquizada, os fatores associados à não utilização de EPI foram: anos de ocorrência do acidente, situação de trabalho formal, reencape de materiais, punção venosa/arterial, administração de medicação, descarte inadequado de materiais, utilização de materiais como lâminas e lancetas e exposição da pele íntegra e não íntegra. Os fatores analisados apresentaram significativa associação com o não uso de EPIs e acidentes de trabalho com material biológico e ressaltam a importância de estratégias de intervenções baseadas na realidade vivenciada por cada ambiente laboral.


Abstract Personal protective equipment (PPE) should be adopted by all professional groups exposed to risks of contact with biological material. The aim is to analyze factors associated with the non-use of PPE by workers affected by occupational accidents with biological material. A quantitative, cross-sectional study was conducted to analyze notification forms of occupational accidents with biological material in municipalities in southern Brazil, from 2014 to 2019. Adjusted and unadjusted data analysis was performed and, subsequently, hierarchical analysis was used, and associations between independent variables and the outcome were established. The frequency of non-use of PPE over the years was 76.5%. At the end of the hierarchical analysis, the factors associated with the non-use of PPE were: years of accident occurrence, formal work status, recapping of materials, venous/arterial puncture, medication administration, inadequate disposal of materials, use of materials such as blades and lancets, and exposure of intact and non-intact skin. The factors analyzed showed a significant association with the non-use of PPE and work accidents with biological material, and highlight the importance of intervention strategies based on the reality experienced in each work environment.

11.
Acta Paul. Enferm. (Online) ; 36: eAPE00582, 2023. tab
Article in Portuguese | LILACS-Express | LILACS, BDENF | ID: biblio-1439044

ABSTRACT

Resumo Objetivo Identificar os fatores associados ao uso de máscara N95 relacionados a alterações de pele entre profissionais de saúde do Norte do Brasil durante a pandemia de COVID-19. Métodos Estudo multicêntrico realizado na região Norte do Brasil no período de outubro a dezembro de 2020, com 1.684 profissionais de saúde que atuaram na assistência à saúde durante a pandemia da COVID-19. Os participantes foram convidados via mídias sociais e as informações coletadas eletronicamente foram armazenadas na plataforma Survey Monkey. Foi usada estatística descritiva para caracterização da amostra, testes de associação (Qui-quadrado), com nível de significância estatística em p < 0,05. Os fatores associados ao uso de máscara N95 relacionados a alterações de pele foram determinados por Regressão Logística Binária, nível de significância de 5% (α = 0,05). Resultados Profissionais de saúde do sexo masculino apresentaram 1,708 mais chances de ter alterações de pele. Outros fatores como, o período de troca de máscara N95, ter atuado em hospital de campanha para COVID-19, terapia intensiva, urgência e emergência e ter recebido alguma capacitação ou curso sobre o COVID-19 foram considerados protetores ao desenvolvimento de alterações de pele, enquanto os principais motivos de troca de máscara N95 foram a umidade, perda de vedação, contaminação, danificação (rasgo). Conclusão Concluiu-se que profissionais de saúde do sexo masculino apresentaram mais chances de ter alterações de pele relacionadas ao uso de máscaras N95. Destacaram-se os fatores protetores e torna-se relevante a realização de estudos de intervenção a fim explorar medidas para prevenção destes tipos de lesões.


Resumen Objetivo Identificar los factores asociados al uso de la mascarilla N95 relacionados con las alteraciones en la piel entre profesionales de salud del norte de Brasil durante la pandemia de COVID-19. Métodos Estudio multicéntrico realizado en la región Norte de Brasil, en el período de octubre a diciembre de 2020, con 1.684 profesionales de salud que actuaron en la asistencia a la salud durante la pandemia de COVID-19. Se convocó a los participantes a través de las redes sociales y la información recopilada electrónicamente fue guardada en la plataforma Survey Monkey. Se utilizó la estadística descriptiva para la caracterización de la muestra, pruebas de asociación (Ji-cuadrado), con un nivel de significación estadística de p < 0,05. Los factores asociados al uso de la mascarilla N95 relacionados con alteraciones en la piel fueron determinados por regresión logística binaria, nivel de significación del 5 % (α = 0,05). Resultados Profesionales de salud de sexo masculino tuvieron 1,708 más posibilidades de presentar alteraciones en la piel. Otros factores como el intervalo de tiempo entre los cambios de mascarillas N95, haber trabajado en hospitales de campaña para COVID-19, cuidados intensivos, urgencias y emergencias y haber realizado alguna capacitación o curso sobre COVID-19 fueron considerados protectores del surgimiento de alteraciones en la piel, mientras que los principales motivos para el cambio de la mascarilla N95 fueron la humedad, la pérdida del sellado, la contaminación y daños (rotura). Conclusión Se concluye que los profesionales de la salud de sexo masculino presentaron más probabilidades de tener alteraciones en la piel relacionadas con el uso de mascarillas N95. Se destacaron los factores protectores y resulta importante la realización de estudios experimentales con la finalidad de explorar medidas para la prevención de este tipo de lesiones.


Abstract Objective To identify the factors associated with N95 mask use related to skin changes among health professionals in northern Brazil during the COVID-19 pandemic. Methods This is a multicenter study carried out in northern Brazil, from October to December 2020, with 1,684 health professionals who worked in health care during the COVID-19 pandemic. Participants were invited via social media and the information collected electronically was stored on the Survey Monkey platform. Descriptive statistics were used to characterize the sample, association tests (chi-square), with statistical significance level at p < 0.05. Factors associated with N95 mask ruse elated to skin changes were determined by Binary Logistic Regression, significance level of 5% (α = 0.05). Results Male health professionals were 1.708 more likely to have skin changes. Other factors such as the N95 mask change period, having worked in a COVID-19 field hospital, intensive care, urgency and emergency and having received some training or course on COVID-19 were considered protective against the development of skin changes, while the main reasons for changing the N95 mask were humidity, loss of seal, contamination, damage (tear). Conclusion We concluded that male health professionals were more likely to have skin changes related to N95 mask use. The protective factors were highlighted and it is relevant to carry out intervention studies in order to explore measures to prevent these types of injuries.

12.
Rev. bras. enferm ; 76(supl.4): e20220647, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BDENF | ID: biblio-1521727

ABSTRACT

ABSTRACT Objectives: to describe a technological innovation in the development of an individual, ergonomic, sustainable and effective occupational respiratory protection mask for workers exposed to surgical smoke. Methods: applied, exploratory, quantitative research, using design methods and tools: Sense Intent, Know Context, Know People, Frame Insights, Explore Concepts, Frame Solutions, Realize Offerings, in addition to the Product Development Process tools. It was developed from March 2019 to December 2021. Results: from the prototyping mold, it became possible to represent the abstract to the physical, where all the concepts created in the methodological steps were implemented and the necessary adjustments were made to create the model as a technological innovation, which will have the concept for product commercialization. Conclusions: a mask for protection against surgical smoke (HeLP) was developed, from the design step to the prototype development, being a technological innovation.


RESUMEN Objetivos: describir una innovación tecnológica en el desarrollo de una máscara de protección respiratoria ocupacional individual, ergonómica, sostenible y eficaz para trabajadores expuestos al humo quirúrgico. Métodos: investigación exploratoria aplicada con un enfoque cuantitativo, utilizando métodos y herramientas de diseño: Sense Intent, Know Context, Know People, Frame Insights, Explore Concepts, Frame Solutions, Realize Offers, además de las herramientas del Proceso de Desarrollo de Producto. Fue desarrollado de marzo de 2019 a diciembre de 2021. Resultados: a partir del molde de prototipado, se logró representar lo abstracto a lo físico donde implementó los conceptos creados en las etapas metodológicas y realizó los ajustes necesarios para la creación del modelo como innovación tecnológica en el cual tendrá el concepto para la comercialización del producto. Conclusiones: se desarrolló una máscara de protección contra el humo quirúrgico (HeLP), desde la etapa de diseño hasta el desarrollo del prototipo, configurando una innovación tecnológica.


RESUMO Objetivos: descrever uma inovação tecnológica do desenvolvimento de máscara de proteção ocupacional respiratória individual, ergonômica, sustentável e eficaz para trabalhadores expostos à fumaça cirúrgica. Métodos: pesquisa aplicada, exploratória com abordagem quantitativa, empregando métodos e ferramentas em design: Sense Intent, Know Context, Know People, Frame Insights, Explore Concepts, Frame Solutions, Realize Offerings, além das ferramentas do Processo de Desenvolvimento de Produtos. Foi desenvolvida no período de março de 2019 a dezembro de 2021. Resultados: a partir do molde da prototipagem, tornou-se possível a representação do abstrato para o físico, onde implementou os conceitos criados nas etapas metodológicas e realizou os ajustes necessários para a criação do modelo como uma inovação tecnológica em que terá o conceito para a comercialização do produto. Conclusões: foi desenvolvida uma máscara de proteção contra a fumaça cirúrgica (HeLP), desde a etapa de projeto até o desenvolvimento do protótipo, configurando-se uma inovação tecnológica.

13.
Rev Rene (Online) ; 24: e91858, 2023. tab
Article in Portuguese | LILACS, BDENF | ID: biblio-1521473

ABSTRACT

RESUMO Objetivo analisar os níveis de satisfação, autoconfiança e autoeficácia no uso da simulação clínica entre acadêmicos e profissionais da saúde. Métodos estudo transversal, baseado no Design Science Research Methodology, com 156 profissionais e 149 acadêmicos da área de saúde, que participaram da capacitação para uso de equipamentos de proteção individual na pandemia da COVID-19, mediada por Prática Deliberada em Ciclos Rápidos. Os participantes responderam ao questionário sociolaboral e escalas validadas. Utilizou-se análise descritiva, testes Qui-quadrado e t Student em amostras independentes para análise de dados, considerando-se significativo p<0,05. Resultados verificou-se altos níveis gerais de satisfação (média ± desvio-padrão: 4,72±0,58), autoconfiança (4,44±0,78) e autoeficácia (4,03±1,17) para itens favoráveis). Na comparação, identificou-se diferenças estatísticas significativas em sete itens da escala de satisfação dos estudantes e autoconfiança com aprendizagem, e seis da escala de autoeficácia geral com p<0,05. Conclusão os acadêmicos apresentaram maiores médias relacionadas à satisfação e autoconfiança com aprendizagem, enquanto profissionais apresentaram maiores médias relacionadas à autoeficácia, resultados que corroboram para continuidade de práticas envolvendo simulação clínica, propiciando segurança e qualidade aos procedimentos. Contribuições para a prática os resultados apontam que as atividades contribuíram positivamente, potencializando oportunidades de aprendizagem e vivências práticas, que refletem na excelência das rotinas.


ABSTRACT Objective to analyze the levels of satisfaction, self-confidence, and self-efficacy in clinical simulations among health undergraduates and professionals. Methods cross-sectional study based on Design Science Research Methodology, with 156 health professionals and 149 health undergraduates who participated in an educational session about personal protective equipment use during the COVID-19 pandemic, mediated by Rapid-Cycle Deliberate Practice. Participants responded to a social and work-related questionnaire and to validated scales. For descriptive analysis of independent samples, Chi-squared test and Student's t were used considering p<0.05 as significant. Results we found generally high satisfaction levels (mean ± standard deviation: 4.72±0.58), self-confidence (4.44±0.78), and self-efficacy (4.03±1.17) for favorable items. There were significant statistical differences in seven items in the scale of satisfaction and self-confidence with learning in students, and in six items of the general self-efficacy scale, with p<0.05. Conclusion undergraduates showed higher means of satisfaction and self-confidence with learning, while professionals had higher means of self-efficacy. These results can collaborate for the continuity of clinical simulation practices, increasing procedural safety and quality. Contributions to practice the results show that the activities had a positive contribution, increasing learning opportunities and practical experiences that reflect on the excellence of the routine.


Subject(s)
Personal Protective Equipment , Simulation Training , COVID-19
14.
Rev. Headache Med. (Online) ; 14(2): 77-82, 2023.
Article in English | LILACS-Express | LILACS | ID: biblio-1531752

ABSTRACT

Introduction: Personal Protective Equipment (PPE) is part of the work routine of health professionals, especially during pandemics. During the Covid-19 pandemic, the use of PPE became constant for long working hours, resulting in adverse effects on the health of professionals, especially headache. Objective: In this review, we explore the scientific literature on headache associated with prolonged use of PPE during the coronavirus pandemic. Method: This is a narrative literature review conducted through the PubMed and Web of Science databases according to the following MeSH descriptors: "Face shield", "Headache" and "Covid-19". Articles that analyzed the presence of headache and other adverse events in health professionals in prolonged use of PPE were included. Results: The included studies point to headache as the most prevalent adverse event, which may be a new headache or the worsening of a previous headache. Other effects were also found, such as pressure marks on the skin, hyperemia in contact areas; suffocation; reduced concentration and excessive sweating. Conclusion: The use of PPE for long periods can cause headaches due to external pressure, in addition to other unwanted events.These effects reveal the importance of studies to make PPE more efficient, ensuring protection for the individual without causing discomfort.


Introdução: Os Equipamentos de Proteção Individual (EPI) fazem parte da rotina de trabalho dos profissionais de saúde, principalmente durante as pandemias. Durante a pandemia da Covid-19, o uso de EPI tornou-se constante durante longas jornadas de trabalho, resultando em efeitos adversos à saúde dos profissionais, principalmente cefaleia. Objetivo: Nesta revisão, exploramos a literatura científica sobre cefaleia associada ao uso prolongado de EPI durante a pandemia do coronavírus. Método: Trata-se de uma revisão narrativa da literatura realizada por meio das bases de dados PubMed e Web of Science segundo os seguintes descritores MeSH: "Face Shield", "Headache" e "Covid-19". Foram incluídos artigos que analisaram a presença de cefaleia e outros eventos adversos em profissionais de saúde em uso prolongado de EPI. Resultados: Os estudos incluídos apontam a cefaleia como o evento adverso mais prevalente, podendo ser uma nova cefaleia ou o agravamento de uma cefaleia anterior. Também foram encontrados outros efeitos, como marcas de pressão na pele, hiperemia nas áreas de contato; asfixia; concentração reduzida e transpiração excessiva. Conclusão: O uso de EPI por longos períodos pode causar dores de cabeça por pressão externa, além de outros eventos indesejados. Esses efeitos revelam a importância de estudos para tornar os EPI mais eficientes, garantindo proteção ao indivíduo sem causar desconforto.

15.
Rev. adm. pública (Online) ; 57(6): e20220325, 2023. tab, graf
Article in English | LILACS | ID: biblio-1529524

ABSTRACT

Abstract Under the influence of fiscal federalism and government decentralization theories, a significant part of health systems around the world confronted the COVID-19 pandemic after being shaped or re-shaped by processes of devolution from central to local governments. Procurement of key supplies is one of the components that operate in a decentralized manner, forcing local governments to compete against each other. This was the origin of what has been called the "bidding wars" between subnational governments at the beginning of the pandemic response. These wars led to centralization policies in the United States, the United Kingdom, and the European Union. Yet, less is known about cases from the Global South. By analyzing the procurement of Personal Protective Equipment (PPE) in the 320 Chilean municipalities in charge of primary health, this research provides evidence of the impacts of horizontal government competition on the ability to procure key supplies. In Chile, during the 2020 response to the pandemic, richer municipalities were able to procure more face masks per population, while economies of scale rewarded bigger purchases with lower prices. The authors support the theoretical notion of "concurrency" as a concept that adds nuances to the centralization-decentralization debate. In Chile, for instance, while testing and tracking required decentralization, PPE purchases could have probably benefited from centralization in order to avoid reproducing territorial inequalities.


Resumen Bajo la influencia del federalismo fiscal y las teorías de la descentralización gubernamental, una parte importante de los sistemas de salud de todo el mundo enfrentaron la pandemia de COVID-19 después de haber sido moldeados o reformados por procesos de transferencia de poderes de los gobiernos centrales a los locales. La adquisición de suministros clave es uno de los componentes que opera de manera descentralizada, lo que obliga a los gobiernos locales a competir entre sí. Este fue el origen de lo que se ha llamado las "guerras de licitaciones" entre gobiernos subnacionales al comienzo de la respuesta a la pandemia. Estas guerras llevaron a políticas de centralización en Estados Unidos, Reino Unido y la Unión Europea. Sin embargo, se sabe menos sobre los casos del sur global. Al analizar la adquisición de Equipos de Protección Personal (EPP) en 320 municipios chilenos encargados de la atención primaria de salud, esta investigación proporciona evidencia de los impactos de la competencia gubernamental horizontal en la capacidad de adquirir suministros clave. En Chile, durante la respuesta a la pandemia de 2020, los municipios más ricos pudieron adquirir más mascarillas por habitante, generándose con ello economías de escala que les permitieron acceder a precios más bajos, a diferencia de aquellos municipios con menores recursos. Los autores apoyan la noción teórica de "concurrencia" como un concepto que añade matices al debate sobre centralización-descentralización. En Chile, por ejemplo, si bien el testeo y la trazabilidad de casos SARS-CoV-2 requerían la descentralización de dichas funciones, las compras de EPP probablemente podrían haberse beneficiado de la centralización de los procesos de adquisición para evitar la reproducción de desigualdades territoriales.


Resumo Sob a influência do federalismo fiscal e das teorias de descentralização governamental, uma parte significativa dos sistemas de saúde em todo o mundo enfrentou a pandemia da COVID-19 depois de terem sido moldados ou remodelados por processos de transferência dos governos centrais para os governos locais. A aquisição de suprimentos essenciais é um dos componentes que operam de forma descentralizada, forçando os governos locais a competir entre si. Esta foi a origem do que foi chamado de "guerras de licitações" entre governos subnacionais no início da resposta à pandemia. Essas guerras levaram a políticas de centralização nos Estados Unidos, no Reino Unido e na União Europeia. No entanto, sabe-se menos sobre os casos do Sul Global. Ao analisar a aquisição de Equipamentos de Proteção Individual (EPI) nos 320 municípios chilenos responsáveis pela saúde primária, esta pesquisa fornece evidências dos impactos da competição governamental horizontal na capacidade de adquirir suprimentos essenciais. No Chile, durante a resposta à pandemia de 2020, os municípios mais ricos conseguiram adquirir mais máscaras faciais por população, enquanto as economias de escala recompensaram compras maiores com preços mais baixos. Os autores apoiam a noção teórica de simultaneidade como um conceito que acrescenta nuances ao debate centralização-descentralização. No Chile, por exemplo, embora os testes e o acompanhamento exigissem a descentralização, as compras de EPI poderiam provavelmente ter beneficiado da centralização, a fim de evitar a reprodução de desigualdades territoriais.


Subject(s)
Chile
16.
Rev. bras. enferm ; 76(supl.1): e20220081, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BDENF | ID: biblio-1407485

ABSTRACT

ABSTRACT Objectives: to develop and validate an algorithm to guide professionals in cleaning and disinfecting ambulances after transferring patients with contagious infectious diseases. Methods: the study was conducted between September and November 2021. The developed algorithm was validated by 104 judges, including nurses, physical therapists, and physicians who care for patients with contagious infectious diseases. It used the Delphi technique and content validity index. Results: in the first evaluation, the judges considered the algorithm "unsuitable" and "fully suitable". The algorithm reviewed according to the judges' suggestions was rated between "suitable" and "fully suitable" in the second evaluation. The overall content validity index was 0.960 and 0.998 in the first and second evaluations. Conclusions: the algorithm to guide the cleaning and disinfection of ambulances after transferring patients with contagious infectious diseases was developed and validated by specialists in the field, with consensus among the judges in the second evaluation.


RESUMEN Objetivos: desarrollar y validar algoritmo para orientar profesionales en la limpieza y desinfección de ambulancia tras transferencia de paciente con enfermedades transmisibles. Métodos: estudio realizado entre septiembre y noviembre de 2021. El algoritmo desarrollado fue validado por 104 jueces, incluyendo enfermeros, fisioterapeutas y médicos que asisten a pacientes con enfermedades transmisibles. Utilizada técnica Delphi e índice de validez de contenido. Resultados: en la primera evaluación, los jueces consideraron el algoritmo entre "inadecuado" y "totalmente adecuado". El algoritmo revisado conforme sugestiones de los jueces fue clasificado entre "adecuado" y "totalmente adecuado" en la segunda evaluación. El índice de validez de contenido general fue de 0,960 y 0,998 en la primera y segunda evaluación, respectivamente. Conclusiones: el algoritmo para orientar en la limpieza y desinfección de ambulancia tras transferencia de paciente con enfermedades transmisibles fue construido y validado por especialistas en el área, habiendo consenso entre los jueces en la segunda evaluación.


RESUMO Objetivos: desenvolver e validar um algoritmo para orientar profissionais na limpeza e desinfecção de ambulância após transferência de paciente com doenças infectocontagiosas. Métodos: estudo realizado entre setembro e novembro de 2021. O algoritmo desenvolvido foi validado por 104 juízes, incluindo enfermeiros, fisioterapeutas e médicos que prestam assistência aos pacientes com doenças infectocontagiosas. Utilizaram-se a técnica Delphi e o índice de validade de conteúdo. Resultados: na primeira avaliação, o algoritmo foi considerado pelos juízes entre "inadequado" e "totalmente adequado". O algoritmo revisado segundo as sugestões dos juízes foi classificado entre "adequado" e "totalmente adequado" na segunda avaliação. O índice de validade de conteúdo geral foi de 0,960 e 0,998 na primeira e segunda avaliação, respectivamente. Conclusões: o algoritmo para orientar na limpeza e desinfecção de ambulância após transferência de paciente com doenças infectocontagiosas foi construído e validado por especialistas na área, havendo consenso entre os juízes na segunda avaliação.

17.
J. Transcatheter Interv ; 31: eA20230009., 2023. ilus; tab
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1511103

ABSTRACT

Introdução: As extensões de cateter-guia fornecem maior suporte em intervenções coronárias percutâneas complexas. O ExpressmanTM é uma nova extensão de cateter-guia, e nosso objetivo foi avaliar o impacto de seu uso no sucesso do procedimento e nas complicações ocorridas em um centro de referência de alto volume. Métodos: Analisamos os dados de todos os procedimentos consecutivos em que foi usada uma extensão de cateter-guia ExpressmanTM. A decisão de usar uma extensão de cateter-guia ficou a critério do operador. O sucesso do dispositivo foi definido como o posicionamento bem-sucedido da extensão de cateter-guia dentro do vaso coronário, e o sucesso do procedimento foi definido como <20% de estenose residual e fluxo TIMI 3, sem perda significativa de ramos laterais. Eventos adversos cardíacos e cerebrovasculares maiores foram definidos como a combinação morte por todas as causas, infarto do miocárdio, revascularização do vaso-alvo e acidente vascular cerebral. Resultados: Foram incluídos 34 procedimentos entre abril de 2022 e janeiro de 2023. A maioria dos pacientes era do sexo masculino (59%), e a média de idade foi 66,5 anos. O uso da extensão de cateter-guia não foi planejado antes do procedimento em 17 procedimentos (50%). Os motivos mais comuns para o uso da extensão de cateter-guia foram angulação ou tortuosidade do vaso-alvo e posição desfavorável do óstio coronário. O sucesso do dispositivo foi obtido em 88% e o da revascularização, em 91%. Houve três oclusões de ramo lateral. Durante o acompanhamento clínico intra-hospitalar, não ocorreram sangramento e nem eventos adversos cardíacos e cerebrovasculares maiores. Conclusão: O sucesso do dispositivo e do procedimento foi alto, e a taxa de complicações foi baixa. O uso da extensão de cateter-guia como técnica de resgate em anatomias complexas permitiu o sucesso do procedimento na maioria dos pacientes que, de outro modo, não poderiam ser tratados.


Background: Guide catheter extensions provide increased support in complex percutaneous coronary interventions. The ExpressmanTM is a novel guide catheter extension and the objective was to assess the impact of its use on procedural success and complications in a high-volume reference center. Methods: We analyzed data from all consecutive procedures in which the ExpressmanTM guide catheter extension was used. The decision to use a guide catheter extension was at operator's discretion. Device success was defined as the successful positioning of the guide catheter extension in the coronary vessel and procedural success was defined as <20% residual stenosis and TIMI 3 flow, with no loss of significant side branches. Major adverse cardiac and cerebrovascular events were defined as the composite of all-cause death, myocardial infarction, target vessel revascularization and stroke. Results: From April 2022 to January 2023, 34 procedures were included. The majority of the patients were male (59%) and the mean age was 66.5 years. Guide catheter extension use was not planned pre-procedure in 17 procedures (50%). The most common reasons for guide catheter extension use were target vessel angulation or tortuosity and unfavorable coronary ostium position. Device success was obtained in 88% and revascularization success in 91%. There were three side branch occlusions. During in-hospital clinical follow-up, no major adverse cardiac and cerebrovascular events or major bleeding occurred. Conclusion: The device success and procedural success were high and the rate of complications was low. Guide catheter extension use as bailout technique in complex anatomies allowed procedural success in the vast majority of otherwise untreatable patients.

18.
Porto Alegre; s.n; 2023. 211 f p.
Thesis in Portuguese | LILACS, BDENF | ID: biblio-1425786

ABSTRACT

No final do primeiro trimestre de 2020 a Organização Mundial da Saúde reconheceu a contaminação pelo novo SARS-Cov2 como uma pandemia. Diante disso, encontrar alternativas diante das dificuldades de fornecimento de EPIs, incluindo aqueles de difícil fabricação e considerados descartáveis, como os respiradores do tipo N95 e/ou PFF2, tornou-se uma das tarefas difíceis e primordiais para garantir assistência aos pacientes com a doença do coronavírus (COVID-19). Objetivo: Avaliar a segurança no uso de respiradores descontaminados do tipo PFF2, equipamentos de proteção individual (EPIs) considerados de uso único por profissional de saúde em situações de pandemia. Método: Pesquisa de abordagem de multimétodos. O estudo foi dividido em três desdobramentos metodológicos: uma revisão sistemática com metanálise, um estudo com desenho quase-experimental e um estudo de caso. O relatório da revisão sistemática com metanálise foi desenvolvido em oito bases científicas, de acordo com as orientações de Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA), com busca de publicações entre janeiro de 2020 e agosto de 2022. A pergunta norteadora foi: o reúso e/ou descontaminação de máscaras N95 viabiliza a manutenção da integridade e eficiência de filtração para os profissionais de saúde na prevenção da COVID-19? A meta-análise foi realizada usando meta-regressão, com variação inversa. A avaliação metodológica dos artigos foi realizada através do instrumento Joanna Briggs critical appraisal para ensaios experimentais não randomizados. O quase-experimento e o estudo de caso foram realizados na Central de Materiais e Esterilização (CME), em um hospital público, universitário e federal da região Sul do Brasil. Foi definido o cálculo do tamanho amostral mínimo de seis respiradores PFF2 para cada tipo de intervenção e tempo de uso para o desenvolvimento do quase-experimento. Este cálculo foi baseado no estudo piloto com máscaras novas com simulação de uso, com análise de potência de 90%, com dois desvios- padrão e com nível de confiança de 95%. As amostras foram coletadas de forma não aleatória, com recrutamento sequencial em duas unidades: Unidade de Terapia Intensiva (UTI não- COVID), na qual os profissionais utilizavam respiradores PFF2 por 42 horas, e a UTI-COVID, na qual as máscaras PFF2 foram utilizadas por 6 horas. O período da coleta foi de 60 dias, entre os meses de abril e junho de 2021. Os critérios de inclusão foram: respiradores do tipo PFF2 fornecidos pela instituição para uso profissional contra agentes biológicos, com laudos de certificação de eficiência bacteriológica, e usados pelos profissionais das UTIs COVID e não- COVID, conforme o protocolo. Os critérios de exclusão foram: respiradores com deformidades ou danificados, com perda de integridade aparente, com marcações que não fossem decorrentes de uso, respiradores valvulados, bem como respiradores da UTI não-COVID descartados com tempo de uso inferior ou superior às 42 horas (7 plantões de 6 horas) preconizadas. Os grupos foram divididos por tempo de uso e tipo de intervenção: Grupo Controle, composto de respiradores novos, e nove grupos experimentais adicionais. Foram consideradas como variáveis dependentes quantitativas: os resultados dos testes de resistência à respiração, à penetração do filtro e à inflamabilidade relacionada à segurança do usuário após o processo de descontaminação de respiradores PFF2. Como variáveis independentes qualitativas foram considerados os tipos de processo de descontaminação. As amostras foram analisadas em laboratório tecnológico de materiais e produtos para o controle da qualidade na cidade de São Paulo, certificado pela Rede Brasileira de Laboratórios de Ensaio (RBLE), com base na norma ABNT NBR 13698/2022, avaliando resistência à respiração com fluxo contínuo de inalação e exalação, penetração através do filtro e inflamabilidade. Os dados foram analisados por meio de estatística descritiva. Para analisar se o respirador permaneceu seguro para o uso após a descontaminação em relação ao grupo controle, foi empregado o teste t Student, para verificar a diferença da resistência à respiração (inalação e exalação) e à penetração do filtro da PFF2 entre os grupos foi utilizado o teste Anova. Foram considerados significativos os valores de p <0,05. Para o estudo de caso, foram aplicadas fontes institucionais, registros de tempo e recursos utilizados para a descontaminação de respirador PFF2. Baseado no modelo de IOWA, foi elaborado o fluxo do processo com a identificação das etapas para viabilizar a descontaminação dos respiradores. Posteriormente, foi elaborada uma planilha para coleta dos dados e comparação dos custos diretos no período pré e durante a pandemia. Quanto aos preceitos bioéticos, esta pesquisa foi orientada pela legislação, aprovada pelo comitê de ética da instituição, CAAE 702207717.4.0000.5327, parecer de aprovação n.2.183.123. Resultados: Como resultados da revisão sistemática, sete artigos foram incluídos na extração dos dados e avaliação crítica, e três na meta-análise. Quatro estudos avaliaram a integridade por inspeção visual e dois por microscopia eletrônica. Não se constatou associação entre o aumento do número de ciclos e a redução da filtração em até 10 ciclos. Nenhum estudo foi considerado de alta qualidade metodológica. Quanto aos resultados do quase-experimento, a resistência à respiração da PFF2 se manteve dentro dos limites preconizados pela norma para os diferentes fluxos de pressão (p<=0,001) na comparação entre as máscaras novas e usadas, independente do tempo de uso. Em relação à manutenção da filtração da PFF2, verifica-se que todos os grupos se mantiveram dentro do limite preconizado de penetração (<6%) utilizando cloreto de sódio em um fluxo contínuo de 95l/min. No entanto, constata-se diferença significativa (p=0,002) entre as máscaras descontaminadas e as novas, independentemente do tipo de tratamento no requisito de penetração. Ao avaliar o tempo de uso, as máscaras descontaminadas e utilizadas por 42h apresentaram, quando comparadas às máscaras novas, diferença significativa na penetração (p=0,012). Em relação ao estudo de caso, afirma-se que, no cenário analisado, o custo do processo de descontaminação de respiradores do tipo PFF2 de uso único durante a pandemia da COVID-19 não é justificável em períodos em que não há escassez de recursos. Conclusão: A partir da revisão sistemática, há evidências da manutenção da integridade e filtração após reúso de respiradores N95/PFF2 para prevenir a COVID-19. O quase-experimento ratificou alguns achados da revisão sistemática, mostrando que a descontaminação de máscara PFF2 é viável nos tipos de descontaminações propostos neste estudo, em situações de pandemia, quando avaliados os requisitos de resistência e manutenção da filtragem em acordo com a norma preconizada. Resíduos de suor e/ou maquiagem não se configuraram como fatores impeditivos para manutenção da filtragem dos respiradores PFF2, além de não terem influenciado no risco de maior ou menor inflamabilidade da máscara. Quanto ao custo do processo de descontaminação desses respiradores, a única justificativa viável para a prática da descontaminação seria a indisponibilidade e o desabastecimento deste EPI.


At the end of the first quarter of 2020, the World Health Organization recognized the contamination by the new SARS-Cov2 as a pandemic. Finding alternatives for the difficulties in providing PPE, including those that are difficult to manufacture and are considered disposable, such as N95 and/or PFF2 respirators, became one of the hardest and fundamental tasks to ensure assistance to patients with coronavirus disease (COVID-19). Objective: To evaluate the safety in the use of PFF2 respirators decontaminated type, personal protective equipment (PPE) considered for one-time use by a health professional in pandemic situations. Method: Research was based on a multimethod approach. This study was developed in three methodological unfoldings: a systematic-metanalysis review, a study with a quasi-experimental design and a case-study. The systematic-metanalysis review report was developed based on the orientations of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) on eight scientific basis, looking for publications between January of 2020 and August of 2022. The guiding question was: does the reuse and/or decontamination of N95 masks enable to maintain the integrity and efficiency of filtration for health professionals in the COVID-19 prevention? The metanalysis was carried out using meta-regression with inverse variance. The articles methodological evaluation was performed through the tool Joanna Briggs critical appraisal for not randomized experimental tests. The quasis-experiment and the case study were carried out at the Materials and Sterilization Center, in a public, federal and university hospital in the southern region of Brazil. It was established the sample size calculation minimum of six PFF2 respirators for each type of intervention and time of use for the development of the quasis-experiment. The calculation was based on the pilot study with new masks with simulated use, with power analysis of 90%, with two standard deviations and confidence level of 95%. The samples were collected non-randomly, with sequential recruitment in two units: Intensive Care Unit (non-COVID ICU), in which professionals used PFF2 respirators for 42 hours, and the ICU-COVID, in which PFF2 masks were used for 6 hours. The collection period was of 60 days between the months of April and June of 2021. As inclusion criteria, were used PFF2 respirators for professional use against biological agents provided by the institution, with bacteriological efficiency certification reports, and used by professionals of COVID and non-COVID ICUs, according to the protocol. Exclusion criteria were respirators with deformities or damaged, with apparent loss of integrity, with marks that were not due to use, valved respirators, as well as non-COVID ICU respirators discarded with time of use less than or greater than 42 hours (7 shifts of 6 hours) recommended. The groups were divided by time of use and type of intervention: Control Group, composed of new respirators, and nine additional experimental groups. The following quantitative dependent variables were considered: results of breath resistance tests, of filter penetration and of flammability related to user safety after the decontamination process of PFF2 respirators. As qualitative independent variables, the types of decontamination process were considered. The samples were analyzed in a materials and products technological laboratory for quality control in the city of São Paulo, certified by the Rede Brasileira de Laboratórios de Ensaio (RBLE), based on the ABNT NBR 13698/2022 norm, evaluating the resistance of breathing with a continuous flow of inhalation and exhalation, penetration through the filter and flammability. Data were analyzed using descriptive statistics. To analyze if the respirator remained safe for use after decontamination compared to the control group T Student test was used to verify the difference of breathing resistance (inhalation and exhalation) and to the penetration of the PFF2 filter was used the ANOVA test. Values of p<0.05 were considered significant. For the case study, institutional sources, time registrations and resources used for the decontamination of PFF2 respirator were applied. Based on the IOWA model, the process flow was elaborated with the identification stages to enable respirators decontamination. Afterwards, a spreadsheet was made to collect data and to compare direct costs in the periods of before and during the pandemic. As for the bioethical precepts, this research was guided by the legislation, approved by the institution's ethics committee, CAAE 702207717.4.0000.5327, approval opinion n.2.183.123. Results: As systematic review results, seven articles were included in the data extraction and critical evaluation, and three articles in the metanalysis. Four studies evaluated the integrity by visual inspection and two studies by electronic microscopy. There was not observed any association between the increase in the number of cycles and the filtration reduction in up to ten cycles. Any study was considered of high methodological quality. As for the quasi-experiment results, the PFF2 breathing resistance remained within the limits recommended by the norm for the different pressure flows (p<=0.001) in the comparison between new and used masks, regardless of the time of use. Regarding the PFF2 filtration maintenance, it is verified that all groups remained within the recommended penetration limit (<6%) using sodium chloride in a continuous flow of 95l/min. However, there is a significant difference (p=0.002) between decontaminated and new masks, regardless of the type of treatment in the penetration requirement. When evaluating the time of use, the masks decontaminated and used for 42 hours presented, when compared to new masks, a significant difference in penetration (p=0.012). Regarding the case study, it is stated that, in the scenario analyzed, the costs of PFF2 respirators decontamination process of single use during the COVID-19 pandemic is not justifiable in periods where there is no resource shortage. Conclusion: From the systematic review, there is integrity and filtration maintenance evidence after the reuse of N95/PFF2 respirators to prevent COVID-19. The quasi-experiment ratified findings of systematic review, showing that PFF2 mask decontamination is practicable in the types of decontamination proposed in this study, in pandemic situations, when the resistance and filtering maintenance requirements were evaluated in accordance with the recommended norm. Sweat and/or makeup residues were not configured as deterrent factors for the filtering of PFF2 respirators maintenance, as well as not influencing the risk of greater or lesser flammability of the mask. In terms of decontamination process cost of single-use PFF2 respirators, the only viable justification for the practice of PFF2 masks decontamination would be the unavailability and shortage of this PPE.


Subject(s)
Nursing
19.
Rev. bras. ortop ; 57(6): 968-974, Nov.-Dec. 2022. tab, graf
Article in English | LILACS | ID: biblio-1423630

ABSTRACT

Abstract Objective The present study aims to evaluate the influence of different positioning of the hip femoral prosthesis on the stress and strain over this implant. Methods A femoral prosthesis (Taper - Víncula, Rio Claro, SP, Brazil) was submitted to a stress and strain analysis using the finite element method (FEM) according to the International Organization for Standardization (ISO) 7206-6 Implants for surgery - Partial and total hip joint prostheses - Part 6: Endurance properties testing and performance requirements of neck region of stemmed femoral components standard. The analysis proposed a branch of the physical test with a +/− 5° angle variation on the standard proposed for α and β variables. Results The isolated +/− 5° variation on the α angle, as well as the association of +/− 5° variation on the α and β angles, presented significant statistical differences compared with the control strain (p= 0.027 and 0.021, respectively). Variation on angle β alone did not result in a significant change in the strain of the prosthesis (p= 0.128). The stem positioning with greatest implant strain was α = 5° and β = 14° (p= 0.032). Conclusion A variation on the positioning of the prosthetic femoral stem by +/− 5° in the coronal plane and/or the association of a +/− 5° angle in coronal and sagittal planes significantly influenced implant strain.


Resumo Objetivo Avaliar a influência da variação do posicionamento da prótese femoral do quadril na tensão e na deformação produzidas neste implante. Métodos Utilizou-se a análise de tensão e de deformação da prótese femoral (Taper, Víncula, Rio Claro, SP, Brasil) pelo método de elementos finitos (MEF) de acordo com a norma ISO 7206-6 Implants for surgery - Partial and total hip joint prostheses-Part 6: Endurance properties testing and performance requirements of neck region of stemmed femoral components. A análise propôs uma ramificação do ensaio físico, com variação da angulação de +/− 5° sobre a proposta normativa das variáveis α e β. Resultados Ao comparar com a deformação controle, houve significância estatística com a angulação isolada de +/− 5° do ângulo α, bem como com a associação de +/− 5° nas angulações α e β (p= 0,027 e 0,021, respectivamente). Já com a variação apenas do ângulo β, não houve variação significativa na deformação da prótese (p= 0,128). A posição da haste com maior deformação no implante foi com α = 5° e β = 14° (p= 0,032). Conclusão A variabilidade de posicionamento da haste femoral protética de +/− 5° no plano coronal e/ou a associação da angulação de +/− 5° nos planos coronal e sagital interferiu de forma significativa na deformação do implante.


Subject(s)
Humans , Equipment Failure Analysis , Arthroplasty, Replacement, Hip/adverse effects , Finite Element Analysis , Hip Prosthesis
20.
Nursing (Ed. bras., Impr.) ; 25(287): 7606-7617, abr.2022. tab
Article in English, Portuguese | LILACS, BDENF | ID: biblio-1372529

ABSTRACT

Objetivo: avaliar o desenvolvimento de lesão por pressão em profissionais de saúde desencadeadas pelas máscaras de proteção individual N95, assim como avaliar o uso de barreiras de proteção usadas como interface para prevenção desse tipo de lesão. Método: Trata-se de um estudo transversal desenvolvido de julho de 2020 a julho de 2021. Para a coleta de dados, foi aplicado questionário para avaliar as particularidades da pele, desenvolvimento de lesão, classificação e os fatores de risco para seu desenvolvimento. Para análise estatística foi considerada a significância de p <0,1 e regressão logística múltipla. Resultados: Foram avaliados 85 profissionais, sendo que 91,8% destes apresentaram algum tipo de lesão. Conclusão: Conclui-se que a lesão por pressão relacionada ao uso de máscaras de proteção individual N95 apresentou alta ocorrência nessa população. E embora importantes, barreiras protetoras foram pouco utilizadas devido a questões financeiras da instituição(AU)


Objective: to evaluate the development of pressure injuries triggered by N95 personal protective masks in health professionals, as well as to evaluate the use of protective barriers used as an interface to prevent this type of injury. Method: This is a cross-sectional study developed from July 2020 to July 2021. For data collection, a questionnaire was applied to assess the particularities of the skin, lesion development, classification and risk factors for its development. For statistical analysis, significance of p <0.1 and multiple logistic regression were considered. Results: Eighty-five professionals were evaluated, and 91.8% of them developed some type of injury. Conclusion: Pressure injuries related to the use of N95 personal protective masks were highly prevalent in this population. And although important, protective barriers were under-used due to financial issues in the institution(AU)


Objetivo: evaluar el desarrollo de lesiones por presión en profesionales de la salud provocadas por máscaras de protección personal N95, así como evaluar el uso de barreras protectoras utilizadas como interfaz para prevenir este tipo de lesión. Método: Se trata de un estudio transversal desarrollado de julio de 2020 a julio de 2021. Para la recolección de datos se aplicó un cuestionario para evaluar las particularidades de la piel, desarrollo de la lesión, clasificación y factores de riesgo para su desarrollo. Para el análisis estadístico se consideró la significación de p < 0,1 y la regresión logística múltiple. Resultados: Se evaluaron 85 profesionales, de los cuales el 91,8% presentaba algún tipo de lesión. Conclusión: Se concluye que las lesiones por presión relacionadas con el uso de máscaras de protección personal N95 fueron altamente prevalentes en esta población. Y aunque importantes, las barreras de protección fueron poco utilizadas por cuestiones financieras de la institución.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Young Adult , Pressure Ulcer/etiology , N95 Respirators/adverse effects , COVID-19/prevention & control , Cross-Sectional Studies , Surveys and Questionnaires
SELECTION OF CITATIONS
SEARCH DETAIL